NBE ceramic igniter
This pellet burner igniter is suitable with NBE burners. While installing the igniter make sure that the igniter is fixed normally inside the socket. Igniter should not touch the metal crate in front of the burner head. There should be approximately few millimeters distance. Always make a test ignition cycle!
Suitable values in ignition setup (for ceramic igniters):
- Ignition Power 100%
- Blow ignition start 30%
- Blower ignition mid 30%
- Blow ignition end 30%
- Max.time ignition 15 min
- Ignition start pulse 120 sek