See the table below to select the right boiler and battery tank

The data is true with accumulator heating system in the case where the heating mode of the building is controlled by the heating system. The sizes considered are suitable for all houses. The heating frequency depends on the thermal insulation of the house. The choice is made on a heated surface area, with a height estimate of 2.5 to 2.7 m. The use of 50 cm firewood is common. Cast iron boilers suitable for 50 cm firewood have to be at least six ribs. A larger boiler can also be installed. The larger boiler will reduce the heating time and the number of heating cycles!

Heated area m2 up to 100 100-120 120-150 150-180 180-200 200-220 220-260
Accumulation tank (L)              
100% radiator heating 1000 1200 1500 1800 2000 2200 2500
50% rad + 50% floor heating 700 800 1000 1200 1400 1600 1800
100% Floor heating 550 720 900 1080 1200 1300 1400
UNI 4 5 6 7 8    
Boiler power (kW) 20 28 35 44 53    
Firewood lenght max. (mm) 330 440 550 660 770    
Capacity of the combustion chamber (dm3) 51,6 70,3 89,1 107,8 126,5    
VIADRUS U-26 4 5 6 7 8 9 10
Boiler power (kW) 20-24 27-32 35-40 43-48 50-56 58-64 66-72
Firewood lenght max. (mm) 295 405 515 625 735 845 955
Capacity of the combustion chamber (dm3) 37 51 64,5 78 91 105 118,5